Mouse monoamine oxidase,MAO ELISA Kit
SKU: 24678470904

Mouse monoamine oxidase,MAO ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 7 - Jul 12

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Mouse monoamine oxidase,MAO ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
2. Plasma: Collect specimens using EDTA or heparin as an anticoagulant and centrifuge at 1000×g for 15 minutes at 2-8°C within 30 minutes of collection. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.
3. Cell culture supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.

Pre-Test Preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare a gradient standard working solution: Add 1 mL of universal diluent to the lyophilized standard. Let stand for 15 minutes to completely dissolve, then gently mix (concentration 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 10 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP enzyme conjugate are sequentially added to microwells pre-coated with monoamine oxidase and MAO capture antibodies. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the monoamine oxidase and MAO content in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Mouse
Synonym Mouse monoamine oxidase,MAO ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Monoamine oxidases (MAO) are a family of enzymes that catalyze the oxidation of monoamines, using oxygen to remove their amine groups. They are found bound to the outer mitochondrial membrane of most cell types in the body. The first such enzyme was discovered in the liver by Mary Bernheim in 1928 and named tyramine oxidase. MAO belongs to a family of proteins called flavinamine oxidoreductases. They are important in breaking down monoamines ingested through food and also play a role in inactivating monoamine neurotransmitters.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.156-10 ng/mL
Applications Serum, plasma, cell culture supernatant
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 24678470904

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 2351 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
L
Verified Purchase
Leigh Evans
Lowell, US
★★★★★ 5
Fun for dogs
Color: Green/Alligator, Size: Small
Smaller than I expected, but the two little dogs love it! They love shaking it, making it squeak, tugging it against each other & chasing it when I throw it to fetch. They often sleep laying on it.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 25, 2026
A
Verified Purchase
AngelKlein2275
New York, US
★★★★★ 3
WEIRD feature - requires a water bottle
Color: Cow, Size: Large
Cute, but buyer beware. Maybe the description said this, but who would think to read for this.... You have to insert an empty bottle (like an old water bottle) for it to make the crinkle noise. There is a velcro spot at the base where you can open it and insert the water bottle for the noise factor and your dogs entertainment. I've yet to do that, but feel like my dog is gonna figure out the velcro and get the bottle out in no time. Seems like a waste of money. I could just give her an empty water bottle without the toy for free.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 9, 2026
A
Verified Purchase
Alice
San Leandro, US
★★★★★ 5
Best dog toy!
Color: Multicolor/Alligator & Wild Duck, Size: Medium, Color: Multicolor/Alligator & Wild Duck, Size: Medium
Best dog toy! Most dog toys lady maybe a week or less but this one has been going strong for almost 2 months. Both the squeekers still work on both toys i purchased. My vizsla loves ti squeek and carry it around. We added an empty water bottle in the pocket cavity for some extra fun! Yes, we are still on the same water bottle! Fantastic durability.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 26, 2026
A
Verified Purchase
Amy Jo
West Palm Beach, US
★★★★★ 3
Shows wear quickly
Color: Multicolor/Sheep & Cow, Size: Medium
These are cute but not holding up as well as I had hoped. Quality is ok and the Velcro has held up great. The fabric just isn’t as good as it could be. They are much larger than expected.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 28, 2026
R
Verified Purchase
Rachel
New York, US
★★★★★ 5
Super Sturdy with hours of fun.
Color: Wild Duck, Hare, Squirrel & Alligator, Size: Small
I got the small ones that you cannot put a water bottle in. These toys have held up way better than expected. I am dog sitting a very rough with toys dog named Chunk. He tears up ever. Single. Toy my dog (Ted) has. I bought new ones just for chunk. These appealed to me with the no stuffing, They were cheaper, and have a squeaker. Everything chunk needed. They arrived on time and I thought I wasted my money. They were super soft, like too soft. They felt flimsy and weak. Like 5 minutes with chunk and they be dead. 2 hours with my dog and they would have a rip. So far 2 of them (I set two out) have lasted the whole weekend. The bunny looks very rough and disgusting, but no rips, the squeakers still work, and no random fluff everywhere. I am going to wash the bunny once chunk leaves. My very careful doggo Ted loves them too. He throws them up in the air and catches them, plays tug of war with them, and no rips. They are super sturdy. He can’t wait until Chunk leaves (chunk is 2 and Ted is 12-13) so he can play with them.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 26, 2026

recommand products